Router

VONETS VAR11N-300

Contribute

Projects for this device

Replacement firmware

Replace router software with a customizable system for network controls and community packages.

How to get started

Follow the guide for your exact router version. The first installation may use its web interface, recovery mode or a serial connection.

Setup
Firmware replacement; route varies by router
You’ll need
Exact hardware revision, an appropriate OpenWrt release and its model-specific installation guide.
Hardware revision not specified
Retired support documentedOpen device guide
Hardware revision not specified
Open hardware record

Recorded configuration: 4 MB flash; 32 MB RAM

Device support in source
Retired; check the documented hardware and older release resources.
Sources

Features & details

Check the project and hardware shown for each feature.

OpenWrt

OpenWrt — Source documentation (openwrt.org)

Availability recorded by source
Available 2023

Hardware details

Security

Saved scan

From our saved security research.

Model advisories

Selected highlights

Prioritized by known exploitation, severity, then date.

CVSS 10.0 (v4.0)

VAR11N-300

Vonets WiFi Bridges Stack-based Buffer Overflow

CVE-2024-39791

Affected firmware
Through 3.3.23.6.9
Fix
Fix details in the linked record
Read icscert CVE record
Details and sources

Stack-based buffer overflow vulnerabilities affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an unauthenticated remote attacker to execute arbitrary code.

CVSS 9.4 (v4.0)

VAR11N-300

Vonets WiFi Bridges Improper Check or Handling of Exceptional Conditions

CVE-2024-39815

Affected firmware
Through 3.3.23.6.9
Fix
Fix details in the linked record
Read icscert CVE record
Details and sources

Improper check or handling of exceptional conditions vulnerability affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an unauthenticated remote attacker to cause a denial of service. A specially-crafted HTTP request to pre-authentication resources can crash the service.

CVSS 9.4 (v4.0)

VAR11N-300

Vonets WiFi Bridges Command Injection

CVE-2024-37023

Affected firmware
Through 3.3.23.6.9
Fix
Fix details in the linked record
Read icscert CVE record
Details and sources

Multiple OS command injection vulnerabilities affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an authenticated remote attacker to execute arbitrary OS commands via various endpoint parameters.

CVSS 8.8 (v4.0)

VAR11N-300

Vonets WiFi Bridges Improper Access Control

CVE-2024-29082

Affected firmware
Through 3.3.23.6.9
Fix
Fix details in the linked record
Read icscert CVE record
Details and sources

Improper access control vulnerability affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication and factory reset the device via unprotected goform endpoints.

CVSS 8.7 (v4.0)

VAR11N-300

Vonets WiFi Bridges Path Traversal

CVE-2024-41936

Affected firmware
Through 3.3.23.6.9
Fix
Fix details in the linked record
Read icscert CVE record
Details and sources

A directory traversal vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to read arbitrary files and bypass authentication.

Check more security advisories for this device · CVE.org