Wi Fi extender

Linksys RE7000

Contribute

Projects for this device

Replacement firmware

Replace router software with a customizable system for network controls and community packages.

How to get started

Follow the guide for your exact router version. The first installation may use its web interface, recovery mode or a serial connection.

Setup
Firmware replacement; route varies by router
You’ll need
Exact hardware revision, an appropriate OpenWrt release and its model-specific installation guide.
Hardware revision not specified
Release listed · 25.12.6
Hardware revision not specified
Release listed · 25.12.5
Sources

Hardware details

Security

Saved scan

From our saved security research.

Model advisories

Selected highlights

Prioritized by known exploitation, severity, then date.

CVSS 9.4 (v4.0)

RE7000

Linksys RE7000 PingTest json.cgi platform_event_pingTest os command injection

CVE-2026-86299

Affected firmware
2.0.15
Fix
Fix details in the linked record
Read VulDB CVE record
Details and sources

A vulnerability was detected in Linksys RE7000 2.0.15. This affects the function platform_event_pingTest of the file /cgi-bin/json.cgi?PingTest of the component PingTest Handler. The manipulation of the argument pingTestIp/pingTestPktSize/pingTestTimes results in os command injection. The attack can be launched remotely. The exploit is now public and may be used.

VDB-399463 | Linksys RE7000 PingTest json.cgi platform_event_pingTest os command injection — RE7000 (vuldb.com) ↗VDB-399463 | CTI Indicators (IOB, IOC, TTP, IOA) — RE7000 (vuldb.com) ↗CVE-2026-86299 | CVE Analysis and Report — RE7000 (vuldb.com) ↗Submit #906547 | Linksys RE7000 v2 2.0.15 Command Injection — RE7000 (vuldb.com) ↗

CVSS 8.8 (v3.1)

Linksys RE7000

Linksys RE7000 v2.0.9, v2.0.11, and v2.0.15 have a command execution vulnerability in the "AccessControlList" parameter of the access control function point

CVE-2024-25852

Affected firmware
RE7000: v2.0.9
Fix
Fix details in the linked record
Read mitre CVE record
Details and sources

Linksys RE7000 v2.0.9, v2.0.11, and v2.0.15 have a command execution vulnerability in the "AccessControlList" parameter of the access control function point. An attacker can use the vulnerability to obtain device administrator rights.

CVSS 8.7 (v4.0)

RE7000

Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow

CVE-2025-14136

Affected firmware
1.0.013.001 1.0.04.001 1.0.04.002 1.1.05.003 1.2.07.001
Fix
Fix details in the linked record
Read VulDB CVE record
Details and sources

A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.

VDB-334525 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow — RE7000 (vuldb.com) ↗VDB-334525 | CTI Indicators (IOB, IOC, IOA) — RE7000 (vuldb.com) ↗Submit #697983 | Linksys RE6500、RE6250、RE6300、RE6350、RE7000、RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) Stack-based Buffer Overflow — RE7000 (vuldb.com) ↗

CVSS 8.7 (v4.0)

RE7000

Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so AP_get_wired_clientlist_setClientsName stack-based overflow

CVE-2025-14135

Affected firmware
1.0.013.001 1.0.04.001 1.0.04.002 1.1.05.003 1.2.07.001
Fix
Fix details in the linked record
Read VulDB CVE record
Details and sources

A vulnerability was identified in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function AP_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

VDB-334524 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so AP_get_wired_clientlist_setClientsName stack-based overflow — RE7000 (vuldb.com) ↗VDB-334524 | CTI Indicators (IOB, IOC, IOA) — RE7000 (vuldb.com) ↗Submit #697982 | Linksys RE6500、RE6250、RE6300、RE6350、RE7000、RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) Stack-based Buffer Overflow — RE7000 (vuldb.com) ↗

CVSS 8.7 (v4.0)

RE7000

Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow

CVE-2025-14134

Affected firmware
1.0.013.001 1.0.04.001 1.0.04.002 1.1.05.003 1.2.07.001
Fix
Fix details in the linked record
Read VulDB CVE record
Details and sources

A vulnerability was determined in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function RE2000v2Repeater_get_wireless_clientlist_setClientsName of the file mod_form.so. Executing manipulation of the argument clientsname_0 can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

VDB-334523 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow — RE7000 (vuldb.com) ↗VDB-334523 | CTI Indicators (IOB, IOC, IOA) — RE7000 (vuldb.com) ↗Submit #697981 | Linksys RE6500、RE6250、RE6300、RE6350、RE7000、RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) Stack-based Buffer Overflow — RE7000 (vuldb.com) ↗
Check more security advisories for this device · CVE.org